SKIM200E DIN Rail Insulation Monitor for AC DC Mixed IT System, Low-Frequency Pulse Injection, 1k–999kΩ
Product Details
| Power Supply: | AC 115V-265V 50/60Hz DC 110V-220V | Product Name: | Economical Insulation Monitoring Device |
|---|---|---|---|
| Alarm Threshold: | 1kΩ -99K | Measuring Current: | ≤80μA |
Product Description
- DIN-rail standalone insulation monitoring for IT (ungrounded) AC, DC and mixed AC/DC systems
- Low-frequency pulse square wave injection; measuring range 1 kΩ–999 kΩ
- Adjustable alarm threshold 1 kΩ–99 kΩ via front-panel encoder, no upper-computer software required
- Built-in self-test and monitoring inhibit function for maintenance and withstand-voltage testing
- Two-stage relay outputs: pre-alarm NO contact 250 V/6 A; fault alarm changeover contact (NO+NC) 250 V/3 A
- Wide-range control supply: AC 115–265 V (50/60 Hz) / DC 110–220 V, power ≤2 W
- Compact 36 mm narrow housing, standard 35 mm DIN rail mounting
The SKIM200E is an insulation monitoring device for IT (ungrounded) systems, designed in accordance with IEC 61557-8. It adopts the low-frequency pulse square wave injection method to continuously assess the overall insulation condition of the monitored busbar.
The device injects a 24 V low-amplitude low-frequency pulse square wave into the monitored system. The feedback current signal (≤80 μA) is filtered and processed to calculate the insulation resistance to earth. The low-frequency measurement is unaffected by system capacitive leakage current, so readings remain stable even when busbar capacitance fluctuates, reducing nuisance alarms. Monitoring runs continuously without disturbing normal main-circuit operation.
Important limitation: the SKIM200E monitors overall busbar insulation only. It does NOT output a fault-location signal; it cannot locate individual faulty branch circuits and cannot be paired with branch current transformers or a fault-location unit.
Online monitoring applies to systems with nominal voltage Un ≤ AC 300 V / DC 300 V. For de-energized offline pre-checks, measurement covers up to AC 690 V / DC 690 V.
SKIM200E — DIN-rail standalone insulation monitor with front-panel encoder setting, built-in self-test and inhibit function. Overall bus insulation supervision for AC, DC and mixed AC/DC IT systems only; no branch fault location.
Branch fault-location versions, high-voltage IT network versions and other related models are not covered by this listing. Please contact us with your system voltage and site requirements; our engineer will confirm whether an alternative model is needed before order placement.
- Standalone insulation monitoring for ungrounded AC, DC and mixed AC/DC IT systems
- Low-frequency pulse square wave injection; low measuring current ≤80 μA does not disturb main-circuit operation
- Measuring range 1 kΩ–999 kΩ; alarm threshold 1 kΩ–99 kΩ, adjustable directly on the front encoder
- Stable readings against capacitive leakage current in long cables, inverters and energy storage loops
- Built-in self-test: simulates an insulation drop to verify the measurement channel and relay operation, no external test instrument required during inspection or acceptance
- Monitoring inhibit (enable) function: temporarily suspends monitoring during maintenance and withstand-voltage tests to avoid false alarms
- Pre-alarm relay: 1 NO contact, 250 V/6 A, suitable for direct drive of sound/light beacons
- Fault alarm relay: 1 changeover contact (NO+NC), 250 V/3 A, suitable for safety interlock and shutdown circuits
- Two-stage alarm logic: early pre-alarm on insulation degradation, fault action only when the dangerous threshold is reached
- Wide-range control supply: AC 115–265 V (50/60 Hz) / DC 110–220 V; rated power ≤2 W
- Compact housing 96 * 36 * 70 mm, net weight ≤180 g; standard 35 mm DIN rail mounting
- Operating temperature: -20 °C … +55 °C; relative humidity <95 %
- Overall insulation supervision only; no branch fault location, no connection to branch CTs
- Control circuits of IT systems: machine tool control panels
- Inverter drive cabinets and variable-frequency auxiliary power circuits
- DC panels, DC busbar and DC control circuits
- Energy storage systems and charging equipment control circuits
- Isolated industrial power supply cabinets
- Electrical test and commissioning benches
| Type | Nominal system voltage Un | Supply voltage Us | Display | Fault location | Art. No. |
|---|---|---|---|---|---|
| SKIM200E | Online: ≤ AC 300 V / DC 300 V; offline pre-check: up to AC 690 V / DC 690 V | AC 115–265 V (50/60 Hz) / DC 110–220 V | No LCD; front encoder with threshold setting and status indication | No | SKIM200E |
| Type designation | Description | Art. No. |
|---|---|---|
| Branch current transformers (CTs) | Not applicable to the SKIM200E; this model has no fault-location output | — |
| Coupling device / measuring line | System coupling and measurement line accessories, if required | TBD |
| Terminal set / mounting clips | Terminal cover and mounting accessories | TBD |
| External alarm beacon | Sound/light warning device driven by the pre-alarm contact | TBD |
Signal cables and external alarm beacons are not included in the scope of delivery and must be ordered separately.
| Document | Type | Language | Date / Doc. No. |
|---|---|---|---|
| SKIM200E Datasheet | Datasheet | EN | TBD |
| SKIM200E Operating Manual | Manual | EN | TBD |
| Wiring Diagram | Wiring diagram | EN | TBD |
| Declaration of Conformity | Declaration | EN | TBD |
| Product Brochure | Brochure | EN | TBD |
Product Highlights
SKIM200E DIN-rail insulation monitor for AC/DC/mixed IT systems. Low-frequency pulse injection resists high stray capacitance, avoiding false alarms. Front encoder sets 1kΩ-99kΩ threshold; dual relays enable graded alarms. IEC 61557-8 compliant, ≤2W, built-in self-test/inhibit. 18-month warranty, OEM customization available.
AC DC Mixed IT System Insulation Monitoring Device with Low Frequency Pulse Injection and IEC61557-8 Compliance Insulation Monitor
SKIM200E DIN-rail insulation monitor for AC/DC/mixed IT systems. Low-frequency pulse injection resists high stray capacitance, avoiding false alarms. Front encoder sets 1kΩ-99kΩ threshold; dual relays enable graded alarms. IEC 61557-8 compliant, ≤2W, built-in self-test/inhibit. 18-month warranty, OEM customization available.
SKIM200E DIN Rail Insulation Monitor for AC DC Mixed IT System, Low-Frequency Pulse Injection, 1k–999kΩ
SKIM200E DIN-rail insulation monitor for AC/DC/mixed IT systems. Low-frequency pulse injection resists high stray capacitance, avoiding false alarms. Front encoder sets 1kΩ-99kΩ threshold; dual relays enable graded alarms. IEC 61557-8 compliant, ≤2W, built-in self-test/inhibit. 18-month warranty, OEM customization available.
Tropical Factory Insulation Monitoring Device with Wide Voltage Tolerant and Anti Nuisance Alarm for IT Systems
The SKIM600M is a tropical-ready IT insulation monitor for AC690V/DC400V systems, featuring low-frequency injection for stable measurement, wide voltage tolerance, Modbus RS485, and adjustable alarm delay to suppress nuisance alarms. Ideal for palm oil mills and humid industrial sites.
Insulation Monitoring Device with Simultaneous Insulation Resistance and Leakage Capacitance Measurement, Modbus RS-485 Communication and DIN Rail Mounting for IT Systems
The SKIM600M is an IEC 61557-8:2015-certified insulation monitoring device for IT systems up to AC 690 V/DC 400 V. It simultaneously measures insulation resistance and leakage capacitance (<4.5mA) using low-frequency injection without disturbing operation. Features include Modbus RS-485, dual alarm relays, backlit LCD, and DIN rail mounting for reliable, efficient busbar supervision.
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.