Insulation Monitoring Device with Simultaneous Insulation Resistance and Leakage Capacitance Measurement, Modbus RS-485 Communication and DIN Rail Mounting for IT Systems
Product Details
| Value: | <4.5mA | Item: | Permissible Leakage Capacitance (Ce) |
|---|
Product Description
The SKIM600M is an insulation monitoring device designed in accordance with IEC 61557-8:2015 for IT (ungrounded) systems. It uses the low-frequency AC signal injection method to continuously assess the overall insulation condition of the complete busbar.
The device injects a low-amplitude, low-frequency test signal into the AC busbar. The feedback voltage and current signals are filtered and processed to calculate both the insulation resistance R and the total leakage capacitance C of the system to earth. Monitoring runs continuously without disturbing normal main-circuit operation.
- Standalone insulation monitoring for AC IT systems up to AC 690 V / DC 400 V and below
- Low-frequency AC signal injection; the low signal level does not disturb main-circuit operation
- Simultaneous measurement and display of insulation resistance R and leakage capacitance C
- Backlit LCD display with a user-friendly menu for viewing operating parameters
- Internal and external test / reset buttons; automatic and manual reset modes
- Wide-range, multi-specification control power supply input
- Modbus RS-485 interface for transmitting insulation values and alarm status to a PLC or supervisory system
- Adjustable alarm response delay to suppress nuisance alarms from load inrush and switching transients
- Two independent alarm relays with changeover contacts; NO/NC output selectable
- Standard DIN rail mounting for cabinet integration
- Operating temperature: -20 °C … +55 °C
- AC-side connection only; no branch fault location and no connection to branch CTs
SKIM600M — Busbar standalone insulation monitor with integrated backlit LCD and local operating controls. Overall bus insulation supervision only; no branch fault location.
SKIM600FL (related model) — Insulation monitor with branch fault-location output, intended for use with the IFL fault-location system and branch current transformers to identify the faulty circuit.
SKIM600H (related model) — Busbar standalone insulation monitor for 1140 V high-voltage ungrounded IT networks.
- Main circuits and control circuits of IT systems up to AC 690 V / DC 400 V
- Chemical and hazardous-area control cabinets
- Metallurgical and medium-frequency furnace auxiliary power circuits
- Tunnel ventilation and dewatering pump supply
- Marine and onshore auxiliary control circuits
- Water treatment plants and pumping stations
- Electrical test and commissioning benches
| Type | Nominal system voltage Un | Supply voltage Us | Display | Fault location |
|---|---|---|---|---|
| SKIM600M | Up to AC 690 V / DC 400 V | Wide-range control supply (TBD) | Integrated backlit LCD | No |
| SKIM600FL | Up to AC 690 V / DC 400 V | Wide-range control supply (TBD) | With display (TBD) | Yes, via IFL system |
| SKIM600H | 1140 V | TBD | With display (TBD) | No |
| Type designation | Description |
|---|---|
| Branch current transformers (CTs) | Used only with the SKIM600FL fault-location version; not applicable to SKIM600M |
| Coupling device (if required) | System coupling / measuring line accessories |
| Terminal set / mounting clips | Terminal cover and mounting accessories |
- SKIM600M Datasheet
- SKIM600M Operating Manual
- Wiring Diagram
- CE Declaration of Conformity
- Product Brochure
Product Highlights
The SKIM600M is an IEC 61557-8:2015-certified insulation monitoring device for IT systems up to AC 690 V/DC 400 V. It simultaneously measures insulation resistance and leakage capacitance (<4.5mA) using low-frequency injection without disturbing operation. Features include Modbus RS-485, dual alarm relays, backlit LCD, and DIN rail mounting for reliable, efficient busbar supervision.
Tropical Factory Insulation Monitoring Device with Wide Voltage Tolerant and Anti Nuisance Alarm for IT Systems
The SKIM600M is a tropical-ready IT insulation monitor for AC690V/DC400V systems, featuring low-frequency injection for stable measurement, wide voltage tolerance, Modbus RS485, and adjustable alarm delay to suppress nuisance alarms. Ideal for palm oil mills and humid industrial sites.
Insulation Monitoring Device with Simultaneous Insulation Resistance and Leakage Capacitance Measurement, Modbus RS-485 Communication and DIN Rail Mounting for IT Systems
The SKIM600M is an IEC 61557-8:2015-certified insulation monitoring device for IT systems up to AC 690 V/DC 400 V. It simultaneously measures insulation resistance and leakage capacitance (<4.5mA) using low-frequency injection without disturbing operation. Features include Modbus RS-485, dual alarm relays, backlit LCD, and DIN rail mounting for reliable, efficient busbar supervision.
Tropical Factory Insulation Monitoring Device with Wide Voltage Tolerant and Anti Nuisance Alarm for IT Systems
The SKIM600M is a tropical-ready IT insulation monitor for AC690V/DC400V systems, featuring low-frequency injection for stable measurement, wide voltage tolerance, Modbus RS485, and adjustable alarm delay to suppress nuisance alarms. Ideal for palm oil mills and humid industrial sites.
SKIM600FL High-precision IMD Insulation Monitoring Device Seamless Integration With Insulation Fault Location Systems
SKIM600FL Insulation Monitoring Device The SKIM600FL is a high-precision insulation monitoring device designed for main and control circuits in IT systems (unearthed systems) operating below AC690V or AC/DC690V. It is engineered for seamless integration with insulation fault location systems. Key ...
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.